background image

4

Information

channel

number

Default

channel name

Default output destination

Description

6

channel6

Web interface

Receives log information.

7 channel7

Not

specified

Receives log, trap, and debugging
information.

8 channel8

Not

specified

Receives log, trap, and debugging
information.

9 channel9

Log

file

Receives log, trap, and debugging
information.

NOTE:

Configurations for the eight output destinations function independently and take effect only after the
information center is enabled.

Outputting System Information by Source Module

The system is composed of a variety of protocol modules, board drivers, and configuration modules. The

system information can be classified, filtered, and output according to source modules. You can use the
info-center source ? command to view the supported information source modules.

Default Output Rules of System Information

The default output rules define the source modules allowed to output information on each output
destination, the output information type, and the output information level as shown in

Table 3

, which

indicates that by default and in terms of all modules:

All log information is allowed to be output to the Web interface and log file; log information with
severity level equal to or higher than informational is allowed to be output to the log host; log

information with severity level equal to or higher than informational is allowed to be output to the

console, monitor terminal, and log buffer; log information is not allowed to be output to the trap

buffer and the SNMP module.

All trap information is allowed to be output to the console, monitor terminal, log host, Web interface,
and log file; trap information with severity level equal to or higher than informational is allowed to

be output to the trap buffer and SNMP module; trap information is not allowed to be output to the
log buffer.

All debugging information is allowed to be output to the console and monitor terminal; debugging
information is not allowed to be output to the log host, trap buffer, log buffer, the SNMP module,

Web interface, and log file.

Table 3 Default output rules for different output destinations

LOG TRAP DEBUG

Output

destinatio

n

Modules

allowed

Enabled/

disabled

Severity

Enabled/

disabled

Severity

Enabled/

disabled

Severity

Console

default (all
modules)

Enabled

Informatio
nal

Enabled Debug Enabled Debug