Configuration procedure – H3C Technologies H3C SecPath F1000-E User Manual
Page 103
37
Configuration procedure
Step1
Configure Device B
# Enable the NQA server and configure the listening IP address as 10.2.2.2 and port number as 9000.
[DeviceB] nqa server enable
[DeviceB] nqa server tcp-connect 10.2.2.2 9000
Step2
Configure Device A
# Create a TCP test group and configure related test parameters.
[DeviceA] nqa entry admin test
[DeviceA-nqa-admin-test] type tcp
[DeviceA-nqa-admin-test-tcp] destination ip 10.2.2.2
[DeviceA-nqa-admin-test-tcp] destination port 9000
# Enable the saving of history records.
[DeviceA-nqa-admin-test-tcp] history-record enable
[DeviceA-nqa-admin-test-tcp] quit
# Enable TCP test.
[DeviceA] nqa schedule admin test start-time now lifetime forever
# Disable TCP test after the test begins for a period of time.
[DeviceA] undo nqa schedule admin test
# Display results of the last TCP test.
[DeviceA] display nqa result admin test
NQA entry (admin admin, tag test) test results:
Destination IP address: 10.2.2.2
Send operation times: 1 Receive response times: 1
Min/Max/Average round trip time: 13/13/13
Square-Sum of round trip time: 169
Last succeeded probe time: 2007-11-22 10:27:25.1
Extended results:
Packet loss in test: 0%
Failures due to timeout: 0
Failures due to disconnect: 0
Failures due to no connection: 0
Failures due to sequence error: 0
Failures due to internal error: 0
Failures due to other errors: 0
Packet(s) arrived late: 0
# Display the history of TCP tests.
[DeviceA] display nqa history admin test
NQA entry (admin admin, tag test) history record(s):
Index Response Status Time
1 13 Succeeded 2007-11-22 10:27:25.1