Configuration System

clock configured

Example

If the value of the original system
clock ± “zone-offset” is not in the
summer-time range, the system

clock configured is the original

system clock ± “zone-offset”.

Configure: clock timezone zone-time
add 1 and clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2
System clock configured: 02:00:00
zone-time Sat 01/01/2005

2 and 3 or 3 and 2

If the value of the original system
clock ± “zone-offset” is in the
summer-time range, the system

clock configured is the original

system clock ± “zone-offset”

+ ”summer-offset”.

Configure: clock timezone zone-time
add 1 and clock summer-time ss one-off
1:00 2005/1/1 1:00 2005/8/8 2
System clock configured: 04:00:00 ss
Sat 01/01/2005

If the value of
"date-time"±"zone-offset" is not in

the summer-time range, the system
clock configured is

"date-time"±"zone-offset".

Configure: clock datetime 1:00
2007/1/1, clock timezone zone-time

add 1 and clock summer-time ss one-off
1:00 2008/1/1 1:00 2008/8/8 2
System clock configured: 02:00:00
zone-time Mon 01/01/2007

1, 2 and 3 or 1, 3 and 2

If the value of
"date-time"±"zone-offset" is in the

summer-time range, the system

clock configured is

"date-time"±"zone-offset"+”summ
er-offset”.

Configure: clock datetime 1:00
2007/1/1, clock timezone zone-time

add 1 and clock summer-time ss one-off

1:00 2007/1/1 1:00 2007/8/8 2
System clock configured: 04:00:00 ss

Mon 01/01/2007

If date-time is not in the daylight
saving time range, the system clock

configured is date-time.

Configure: clock timezone zone-time
add 1, clock summer-time ss one-off

1:00 2008/1/1 1:00 2008/8/8 2
and clock datetime 1:00 2007/1/1
System clock configured: 01:00:00
zone-time Mon 01/01/2007

Configure: clock timezone zone-time
add 1, clock summer-time ss one-off

1:00 2008/1/1 1:00 2008/8/8 2

and clock datetime 1:30 2008/1/1
System clock configured: 23:30:00

zone-time Mon 12/31/2007

[1], 2, 3 and 1 or [1], 3, 2
and 1

date-time is in the daylight saving
time range:
If the value of
“date-time”-“summer-offset” is not

in the summer-time range, the

system clock configured is
“date-time”-“summer-offset”;

If the value of

“date-time”-“summer-offset” is in

the summer-time range, the system
clock configured is date-time.

Configure: clock timezone zone-time
add 1, clock summer-time ss one-off

1:00 2008/1/1 1:00 2008/8/8 2
and clock datetime 3:00 2008/1/1
System clock configured: 03:00:00 ss
Tue 01/01/2008