Table 10-4, Interface type assignments, Fru information and sensor data records – Artesyn ATCA-7470 Installation and Use (October 2014) User Manual
Page 255

FRU Information and Sensor Data Records
ATCA-7470 Installation and Use (6806800P15K)
255
2
1
MAC Address Count (M) (specifying a continuous pool of MAC
addresses starting with the MAC address specified in this
descriptor)
M = 1: this descriptor specifies one MAC address
M > 1: this descriptor specifies a pool of MAC addresses with M
count
3
6
MAC Address. (Canonical form, the LSB (least significant bit) first.
Table 10-4 Interface Type Assignments
Interface Type
Description
01h
ATCA Base Interface
02h
ATCA Fabric Interface
03h
Front/Rear Panel
04h
Mezzanine Module
05h
Serial over LAN (SOL)
06h
Fibre Channel / WWPN
07h
AMC/MicroTCA Common Options Region
08h
AMC/MicroTCA Fat Pipe Region
09h
AMC/MicroTCA Extended Fat Pipe Region
10h
ATCA Update Channel
11h
Multi-type (Base, Fabric, and Update channel (or two types of it) are
connected to a onboard switch)
11h - FFh
reserved
Table 10-3 Artesyn MAC Address Descriptor (continued)
Offset
Length
Description