6.4.22 CPU Type and Presence Detection Register

6.4.23 Memory Temperature Status Register

Table 6-50 CPU Type and Presence Detection Register

Address Offset: 0x54

Bit

Description

Default

Access

0

CPU0 Type Identification (Status of signal CPU0_TYPE_IVY_)
0: IVY-Bridge
1: Sandy-Bridge

Ext.

r

1

CPU1 Type Identification (Status of signal CPU1_TYPE_IVY_)
0: IVY-Bridge
1: Sandy-Bridge

Ext.

r

2

CPU0 Presence Detection (Status of signal CPU0_SKTOCC_)
0: CPU present in socket
1: CPU not present. Socket is empty.

Ext.

r

3

CPU1 Presence Detection (Status of signal CPU1_SKTOCC_)
0: CPU present in socket
1: CPU not present. Socket is empty.

Ext.

r

7:4

Reserved

0

r

Table 6-51 Memory Temperature Status Register

Address Offset: 0x55

Bit

Description

Default

Access

0

Represents the temperature status of CPU0 memory channel 0,1
0: Temperature threshold crossed
1: Normal working temperature

Ext.

r