22 cpu type and presence detection register, 23 memory temperature status register, Table 6-50 – Artesyn ATCA-7470 Installation and Use (October 2014) User Manual
Page 182: Cpu type and presence detection register, Table 6-51, Memory temperature status register, Maps and registers

Maps and Registers
ATCA-7470 Installation and Use (6806800P15K)
182
6.4.22 CPU Type and Presence Detection Register
6.4.23 Memory Temperature Status Register
Table 6-50 CPU Type and Presence Detection Register
Address Offset: 0x54
Bit
Description
Default
Access
0
CPU0 Type Identification (Status of signal CPU0_TYPE_IVY_)
0: IVY-Bridge
1: Sandy-Bridge
Ext.
r
1
CPU1 Type Identification (Status of signal CPU1_TYPE_IVY_)
0: IVY-Bridge
1: Sandy-Bridge
Ext.
r
2
CPU0 Presence Detection (Status of signal CPU0_SKTOCC_)
0: CPU present in socket
1: CPU not present. Socket is empty.
Ext.
r
3
CPU1 Presence Detection (Status of signal CPU1_SKTOCC_)
0: CPU present in socket
1: CPU not present. Socket is empty.
Ext.
r
7:4
Reserved
0
r
Table 6-51 Memory Temperature Status Register
Address Offset: 0x55
Bit
Description
Default
Access
0
Represents the temperature status of CPU0 memory channel 0,1
0: Temperature threshold crossed
1: Normal working temperature
Ext.
r