4 pigeon point specific commands, Table 9-28, Pigeon point extension commands – Artesyn ATCA-7470 Installation and Use (October 2014) User Manual
Page 231: Supported ipmi commands

Supported IPMI Commands
ATCA-7470 Installation and Use (6806800P15K)
231
9.4
Pigeon Point Specific Commands
The IPMC supports additional IPMI commands that are specific to Pigeon Point. This section
provides detailed descriptions of those extensions:
Response Data
1
Completion Code. Generic plus the following command-
specific completion codes:
80h = feature selector not supported.
2
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
5
Feature Configuration
00h = disabled (Feature Selector = E0)
01h = enabled (Feature Selector = E0)
02h – C0h = reserved
C1h = enabled and activated (Feature Selector = E0)
C2h – FFh = reserved
6
Persistency / Duration
Table 9-27 Get Feature Configuration Command (continued)
Byte Data
Field
Table 9-28 Pigeon Point Extension Commands
Command
NetFn
(Request/Response)
CMD
0x2E/0x2F
0x00
Get Serial Interface Properties
0x2E/0x2F
0x01
Set Serial Interface Properties
0x2E/0x2F
0x02
Get Debug Level
0x2E/0x2F
0x03
Set Debug Level
0x2E/0x2F
0x04