Maps and Registers

ATCA-7470 Installation and Use (6806800P15K)

189

When at least one bit of the

Table "Telecom Clock Monitor Out of Range Register" on page 189

is set, the corresponding status bit CLK_MONITOR_OUT_OF_RANGE of

Table "Telecom

Interrupt Control/Status Register" on page 167

is also set.

7:5

Reserved

0

r

Table 6-62 Telecom Clock Monitor Out of Range Register

Address: 0x63

Bit

Description

Default

Access

4:0

Frequency of supervised Telecom Clock 0 to 4 is out of range.
Gate Mode:
Corresponding bit is set when the number of positive Clock
edges within the selected time base is:
< Lower limit or
> Upper limit
Period Mode:
Corresponding bit is set when the Clock 0 Period within the
selected time base is:
< Lower limit or
> Upper limit
Clearing bit triggers new sequence of measurements.

0

LPC: r/w1c

7:5

Reserved

0

r

Table 6-63 Telecom Clock Monitor Select Register

Address: 0x64

Bit

Description

Default

Access

2:0

Select supervised Telecom Clocks. See

Table "Supervised Telecom

Clocks Reference List" on page 188

.

0-4: Select corresponding clock
5-7: Reserved

0

LPC: r/w