beautypg.com

Maps and registers – Artesyn ATCA-7470 Installation and Use (October 2014) User Manual

Page 191

background image

Maps and Registers

ATCA-7470 Installation and Use (6806800P15K)

191

Select Time base for clock supervision with Period Mode:
0: Period Counter incremented with each master clock
1: Period Counter incremented with each 2nd master clock
2: Period Counter incremented with each 4th master clock
3: Period Counter incremented with each 8h master clock
4: Period Counter incremented with each 16th master clock
5: Period Counter incremented with each 32th master clock
6: Period Counter incremented with each 64th master clock
7: Period Counter incremented with each 128th master clock
8: Period Counter incremented with each 256th master clock
9 and all others: Period Counter incremented with each 512th master
clock

7:3

Reserved

0

r

7

Measurement Mode:
0: Gate Mode. Count positive clock edges during open gate.
1: Period Mode. Count number of clocks which fit in one period.

0

LPC: r/w

Table 6-64 Telecom Clock Monitor Time Base Register (continued)

Address: 0x68

Bit

Description

Defaul
t

Access