Select Time base for clock supervision with Period Mode:
0: Period Counter incremented with each master clock
1: Period Counter incremented with each 2nd master clock
2: Period Counter incremented with each 4th master clock
3: Period Counter incremented with each 8h master clock
4: Period Counter incremented with each 16th master clock
5: Period Counter incremented with each 32th master clock
6: Period Counter incremented with each 64th master clock
7: Period Counter incremented with each 128th master clock
8: Period Counter incremented with each 256th master clock
9 and all others: Period Counter incremented with each 512th master
clock
7:3
Reserved
0
r
7
Measurement Mode:
0: Gate Mode. Count positive clock edges during open gate.
1: Period Mode. Count number of clocks which fit in one period.
0
LPC: r/w
Table 6-64 Telecom Clock Monitor Time Base Register (continued)
Address: 0x68
Bit
Description
Defaul
t
Access