18 set payload shutdown time-out command, 19 get module state command, Table 9-47 – Artesyn ATCA-7470 Installation and Use (October 2014) User Manual
Page 248: Set payload shutdown time-out command description, Table 9-48, Get module state command description, Ime-out, Supported ipmi commands

Supported IPMI Commands
ATCA-7470 Installation and Use (6806800P15K)
248
9.4.18 Set Payload Shutdown Time-Out Command
The Set Payload Shutdown Time-Out command is defined as follows.
9.4.19 Get Module State Command
The Get Module State command is used to query the state of a module (RTM with site ID1)
using any of the external interfaces.
Table 9-47 Set Payload Shutdown Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4:5
Time-Out measured in hundreds of milliseconds, LSB first
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 9-48 Get Module State Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Module Site ID
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00