Item
Specification
Agency Approvals
UL and cUL
UL508C File E145959
CE mark
Low Voltage Directive and
Electromagnetic Compatibility Directive
Certificate of Conformity from TUV Product Service
Environmental
Operating Temperature
1398-DDM-010 or 1398-DDM-010X,
1398-DDM-020 or 1398-DDM-020X,
1398-DDM-050 or 1398-DDM-050X,
1398-DDM-075 or 1398-DDM-075X,
1398-DDM-150 or 1398-DDM-150X
0
o
C to 55
o
C (32
o
F to 131
o
F)
0
o
C to 55
o
C (32
o
F to 131
o
F)
0
o
C to 55
o
C (32
o
F to 131
o
F)
0
o
C to 55
o
C (32
o
F to 131
o
F)
0
o
C to 50
o
C (32
o
F to 122
o
F)
Storage Temperature
-40
o
C to 70
o
C (-40
o
F to 158
o
F)
Humidity
5% to 95% non-condensing
Altitude
1500 meters (5000 feet)
Derate 3% for each 300 m above 1500 m (1000 ft. above
5000 ft.)
Vibration
10 to 2000 Hz @ 2g
Shock
15g 11 millisecond half sine
Weight
1398-DDM-010 or 1398-DDM-010X,
1398-DDM-020 or 1398-DDM-020X,
1398-DDM-050 or 1398-DDM-050X,
1398-DDM-075 or 1398-DDM-075X,
1398-DDM-150 or 1398-DDM-150X
5.80 Kg (13.78 lbs)
6.36 Kg (14.02 lbs)
6.48 Kg (14.28 lbs)
9.67 Kg (21.32 lbs)
14.06 Kg (31.00 lbs)
Dielectric Withstanding Voltage (HI-Pot)
Main AC
1000 VAC for 1 minute, <5.0mA leakage current
Auxiliary AC
1414 (1500) VDC for 1 minute, <5.0mA leakage current
NOTE: EMI filter capacitors on Aux AC require
VDC tests.
Motor Encoder Interface
Power Output
5 to 7 Volts DC, Adjustable, Automatic Sensing, Fused
Encoder Inputs
A/B, Differential, 26LS33 input, 1 MHz (4 MHz Quadra-
ture) Maximum Signal Frequency, Line Break Detection,
1/T Low Speed Measurement
Thermostat Inputs
Normally closed
Hall Inputs
Single-ended, 5 Volt Logic
ABS Input
0 to 5 Volt, 10-bit
User Interface
Serial Port
RS-232 or four wire RS-485,
1200 to 19200 baud
Daisy-chain connections accommodated by
two connectors
Status Display
7 segment LED
Address Switch
16-position Rotary DIP
Digital Inputs