Connection diagram, Configuration, Step/direction controller connection diagram – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual
Page 142
Publication 1398-5.0 – October 1998
8-18
Application and Configuration Examples
6. Connect the drive to a 100/240 VDC, 50/60 Hz power source
appropriate to the drive:
• Single Phase: 1398-DDM-010, 1398-DDM-010X,
1398-DDM-020, 1398-DDM-020X, 1398-DDM-030,
1398-DDM-030X, 1398-DDM-075 or 1398-DDM-075X
• Three Phase: 1398-DDM-075, 1398-DDM-075X,
1398-DDM-150 or 1398-DDM-150X
Connection Diagram
Configuration
Carefully check all connections before entering these parameters.
1. Switch the AC Power to ON and verify:
• green DC BUS LED is ON
• seven segment display shows an operational status: A, F or P
(Analog, Follower or Preset mode of operation). Refer to
“Operating Messages” on page 10-1 for an explanation of the
display codes.
Figure 8.4
Step/Direction Controller Connection Diagram
Intro
TB1
Phase R 1
Phase S 2
Phase T 3
Motor Gnd 4
J2
Motor
Encoder
J1
14 STEP+
15 STEP-
16 DIR+
Close to ENABLE Drive
Close to RESET Fault
17 DIR-
Close to Turn ON
21 FAULT
26 +24V
32 INPUT1
Step/Dir
Generator
20 ENABLE
Note 1. Refer to Figure 6.30 and 6.31 for additional details on the Control Interface Cable.
J4
DRIVE
TB1
2 RCV
3 XMT
5 COM
L1
L2/N
Gnd
XMT
RCV
COM
L1
L2/N
Gnd
100-240 VAC
50/60 Hz
Three Phase
Power Source
L3
or
100-240 VAC
50/60 Hz
Single Phase
Power Source
TB1
RESET