Creating Custom Motor Files
D-5
Motor Parameter Definitions
The parameters to configure in a custom motor file are defined below.
ULTRA Master arranges motor parameters in an index card format.
The groupings are:
●
General,
●
Feedback,
●
Current Loop,
●
Electrical, and
●
Ratings.
General Parameters
Motor Model
The motor model field is a text display from which a motor is
selected.
If the motor model text string is changed, ULTRA Master assumes
that a new motor file is being created, and the user must supply a new
filename. This prevents the text string being changed on an existing
motor file. However, a filename may be recycled by:
1. Assign the new file a tentative filename.
2. Delete the old file.
3. Rename the new file, using the old filename.
Table ID
The table ID value determines whether the motor file represents a
standard motor or a custom motor. A table ID in the range of 0 to
65534 identifies a standard motor file, and a table ID of 65535 (also
known as table ID “-1”) identifies a custom motor file. Users may
define motor parameters for multiple custom motors on a PC, but only
one custom motor files may be stored on the drive. (i.e., All custom
motor files have the table ID value of “-1”.)
Motor File
The motor file is the filename of the custom motor file, it is different
from the motor model text field. The filename can have up to 8
characters and must have a .MTR extension. If the motor model text
string is altered, ULTRA Master prompts the user for a new filename.