Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 95

Programming and Parameters
3-41
289
Lin1 Update Rate
Sets the sample rate for the linear channel on the Multi Device Interface (MDI) feedback
option.
Default:
Options:
2
1
2
“1.0 msec”
“0.5 msec”
3
“1.5 msec”
“1.0 msec”
4
“2.0 msec”
290
Linear1 CPR
Specifies the change in Par 276 [FB Opt1 Posit] for one revolution of the motor shaft. This
value is used to scale the calculated speed, based on the change in feedback position.
Units are count per motor revolution (CPR).
Units:
Default:
Min/Max:
CPR
1000
10/100000
✓ 32-bit
Integer
297
Output Curr Disp
Displays measured RMS motor current with a resolution of 1/10 amperes.
Units:
Default:
Min/Max:
Comm Scale:
Amps
0.0
0.0/9999.9
x 10
32-bit
Integer
298
Elapsed Run Time
Displays the total time that the drive has been running (inverter power devices active)
with a resolution of 1/10 hour. This parameter is saved in power EE non-volatile memory.
Units:
Default:
Min/Max:
Comm Scale:
Hrs
0.0
0.0/429496736.0
x 10
✓ 32-bit
Integer
299
Elapsed MWHrs
Displays the total energy the drive has consumed or produced. Calculated from the
absolute magnitude of the product of motor speed and motor torque (power),
accumulated over time. This value will increase in both regen and motoring modes of
operation.
Units:
Default:
Min/Max:
Comm Scale:
MWHrs
0.0
0.0/429496736.0
x 10
✓ 32-bit
Integer
300
Motor Spd Fdbk
Displays measured motor speed information from the selected feedback device.
Units:
Default:
Min/Max:
Comm Scale:
RPM
0.0000
-/+14112.0000
Par 4 [Motor NP RPM] = 1.0
Real
301
Motor Speed Ref
Displays the speed reference value, after the limit function. This is the input to the error
calculator and speed regulator.
Units:
Default:
Min/Max:
Comm Scale:
RPM
0.0000
-/+14112.0000
Par 4 [Motor NP RPM] = 1.0
Real
302
Spd Reg PI Out
Displays the output of the speed regulator. This is the input to torque control. A value of
1.0 represents base torque of the motor.
Units:
Default:
Min/Max:
P.U.
0.0000
-/+8.0000
Real
303
Motor Torque Ref
Displays the reference value of motor torque. The actual value of the motor torque is
within 5% of this value.
Units:
Default:
Min/Max:
P.U.
0.0000
-/+8.0000
Real
No.
Name
Description
Values
Li
nkab
le
Read
-Wr
it
e
Da
ta
T