Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 145

Programming and Parameters
3-91
No.
Name
Description
Value
Li
nkab
le
Read
-Wr
it
e
Da
ta
T
ype
1213
SL Buf Int Tx26
Provides integer data for Direct Transmit word 26, if the data type for word 26 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1214
SL Buf Real Tx26
Provides floating point (real) data for Direct Transmit word 26, if the data type for word 26
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ real
1215
SL Buf Int Tx27
Provides integer data for Direct Transmit word 27, if the data type for word 27 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1216
SL Buf Real Tx27
Provides floating point (real) data for Direct Transmit word 27, if the data type for word 27
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1217
SL Buf Int Tx28
Provides integer data for Direct Transmit word 28, if the data type for word 28 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1218
SL Buf Real Tx28
Provides floating point (real) data for Direct Transmit word 28, if the data type for word 28
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1219
SL Buf Int Tx29
Provides integer data for Direct Transmit word 29, if the data type for word 29 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1220
SL Buf Real Tx29
Provides floating point (real) data for Direct Transmit word 29, if the data type for word 29
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1226
SL Comm TP Sel
Enter or write a value to select SynchLink data displayed by Par 1227 [SL Comm TP
Data].
Default:
Options:
0
0
1
2
3
4
5
6
7
8
9
10
11
12
“Zero”
“Zero”
13 “BufSeqErrTim”
“SL MultA Src”
14 “Rx Sys Rev”
“SL Mult A In”
15 “Tx Axis Size”
“SL Mult B In”
16 “Tx Dir Size”
“SL Mult Out”
17 “Tx Buf Size”
“Rx Axis Size”
18 “Tx Pkg Size”
“Rx Dir Size”
19 “Tx Seq Cnt”
“Rx Buf Size”
20 “Tx Index 0”
“Rx Pkg Size”
21 “Tx Index 1”
“Rx Seq Cnt”
22 “Tx Index 2”
“Rx Index 0”
23 “Rx Vendor ID”
“Rx Index 1”
24 “Rx ModuleTyp”
“Rx Index 2”
25 “Rx Serial #”
1227
SL Comm TP Data
Displays data selected by Par 1226 [SL Comm TP Sel].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1228
SL Error History
Displays SynchLink faults which have occurred since the last fault clear operation or power cycle.
• Bit 0 [Sync Loss] indicates SynchLink communication has failed, after it had been established
• Bit 1 [Rx Loss] indicates the receive port is not receiving data, and the receive port configuration is set to receive data
• Bit 2 [Many BOF Err] indicates the number of Beginning Of Frame (BOF) errors exceeds limit set by Par 1235 [SL BOF Err Limit]
• Bit 3 [Many CRC Err] indicates the number of Cyclic Redundancy Check (CRC) errors exceeds limit set by Par 1234 [SL CRC Err Limit]
• Bit 4 [Pckg Msg Err] indicates the received package sequence number has not matched for 1.0S
• Bit 5 [CommForm Err] indicates the format of received data does not match the configuration of the receive port
• Bit 6 [Sys Rev Err] indicates the system revision in the received data does not match the value of Par 1001 [SynchLink Rev]
• Bit 7 [Mult TKeeper] indicates more than one node on the SynchLink system is configured as a time keeper
Options
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Mult
TK
eep
er
Sy
s R
ev
Er
r
CommF
or
m E
rr
Pc
kg Msg Err
Man
y CRC Err
Man
y BOF Err
Rx
Lo
ss
Sy
nc Los
s
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = True
1 = False