Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 143
Programming and Parameters
3-89
No.
Name
Description
Value
Li
nk
ab
le
R
ead-
Wri
te
D
ata
T
ype
1167
SL Buf Int Tx03
Provides integer data for Direct Transmit word 3, if the data type for word 3 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1168
SL Buf Real Tx03
Provides floating point (real) data for Direct Transmit word 3, if the data type for word 3
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1169
SL Buf Int Tx04
Provides integer data for Direct Transmit word 4, if the data type for word 4 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1170
SL Buf Real Tx04
Provides floating point (real) data for Direct Transmit word 4, if the data type for word 4
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1171
SL Buf Int Tx05
Provides integer data for Direct Transmit word 5, if the data type for word 5 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1172
SL Buf Real Tx05
Provides floating point (real) data for Direct Transmit word 5, if the data type for word 5
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1173
SL Buf Int Tx06
Provides integer data for Direct Transmit word 6, if the data type for word 6 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1174
SL Buf Real Tx06
Provides floating point (real) data for Direct Transmit word 6, if the data type for word 6
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1175
SL Buf Int Tx07
Provides integer data for Direct Transmit word 7, if the data type for word 7 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1176
SL Buf Real Tx07
Provides floating point (real) data for Direct Transmit word 7, if the data type for word 7
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1177
SL Buf Int Tx08
Provides integer data for Direct Transmit word 8, if the data type for word 8 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1178
SL Buf Real Tx08
Provides floating point (real) data for Direct Transmit word 8, if the data type for word 8
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1179
SL Buf Int Tx09
Provides integer data for Direct Transmit word 9, if the data type for word 9 indicated in Par
1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1180
SL Buf Real Tx09
Provides floating point (real) data for Direct Transmit word 9, if the data type for word 9
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1181
SL Buf Int Tx10
Provides integer data for Direct Transmit word 10, if the data type for word 10 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1182
SL Buf Real Tx10
Provides floating point (real) data for Direct Transmit word 10, if the data type for word 10
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1183
SL Buf Int Tx11
Provides integer data for Direct Transmit word 11, if the data type for word 11 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1184
SL Buf Real Tx11
Provides floating point (real) data for Direct Transmit word 11, if the data type for word 11
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1185
SL Buf Int Tx12
Provides integer data for Direct Transmit word 12, if the data type for word 12 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1186
SL Buf Real Tx12
Provides floating point (real) data for Direct Transmit word 12, if the data type for word 12
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1187
SL Buf Int Tx13
Provides integer data for Direct Transmit word 13, if the data type for word 13 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1188
SL Buf Real Tx13
Provides floating point (real) data for Direct Transmit word 13, if the data type for word 13
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1189
SL Buf Int Tx14
Provides integer data for Direct Transmit word 14, if the data type for word 14 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer