Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 139

Programming and Parameters
3-85
1078
SL Buf Real Rx02
Displays the floating point (real) value of the Buffered Received Data for word 2. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1077 [SL Buf Int Rx02].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1079
SL Buf Int Rx03
Displays the integer value of the Buffered Received Data for word 3. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1080 [SL Buf Real Rx03].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1080
SL Buf Real Rx03
Displays the floating point (real) value of the Buffered Received Data for word 3. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1079 [SL Buf Int Rx03].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1081
SL Buf Int Rx04
Displays the integer value of the Buffered Received Data for word 4. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1082 [SL Buf Real Rx04].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1082
SL Buf Real Rx04
Displays the floating point (real) value of the Buffered Received Data for word 4. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1081 [SL Buf Int Rx04].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1083
SL Buf Int Rx05
Displays the integer value of the Buffered Received Data for word 5. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1084 [SL Buf Real Rx05].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1084
SL Buf Real Rx05
Displays the floating point (real) value of the Buffered Received Data for word 5. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1083 [SL Buf Int Rx05].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1085
SL Buf Int Rx06
Displays the integer value of the Buffered Received Data for word 6. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1086 [SL Buf Real Rx06].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1086
SL Buf Real Rx06
Displays the floating point (real) value of the Buffered Received Data for word 6. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1085 [SL Buf Int Rx06].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1087
SL Buf Int Rx07
Displays the integer value of the Buffered Received Data for word 7. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1088 [SL Buf Real Rx07].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1088
SL Buf Real Rx07
Displays the floating point (real) value of the Buffered Received Data for word 7. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1087 [SL Buf Int Rx07].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1089
SL Buf Int Rx08
Displays the integer value of the Buffered Received Data for word 8. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1090 [SL Buf Real Rx08].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1090
SL Buf Real Rx08
Displays the floating point (real) value of the Buffered Received Data for word 8. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1089 [SL Buf Int Rx08].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1091
SL Buf Int Rx09
Displays the integer value of the Buffered Received Data for word 9. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1092 [SL Buf Real Rx09].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1092
SL Buf Real Rx09
Displays the floating point (real) value of the Buffered Received Data for word 9. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1091 [SL Buf Int Rx09].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1093
SL Buf Int Rx10
Displays the integer value of the Buffered Received Data for word 10. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1094 [SL Buf Real Rx10].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
1094
SL Buf Real Rx10
Displays the floating point (real) value of the Buffered Received Data for word 10. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1093 [SL Buf Int Rx10].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1095
SL Buf Int Rx11
Displays the integer value of the Buffered Received Data for word 11. Data transmitted
from one node to another must be the same data type. This parameter is paired with Par
1096 [SL Buf Real Rx11].
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
No.
Name
Description
Values
Li
nkab
le
Read
-Wr
it
e
Da
ta
T
ype