Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 142
![background image](/manuals/577236/142/background.png)
3-88
Programming and Parameters
1132
SL Buf Real Rx29
Displays the floating point (real) value of the Buffered Received Data for word 29. Data
transmitted from one node to another must be the same data type. This parameter is
paired with Par 1131 [SL Buf Int Rx29].
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
1140
Tx Dir Data Type
Indicates the data type of each Direct Transmit word. If the word's bit is set the data type is floating point (real). If the word’s bit is not set the data type is integer. Use
the Peer Communication window to configure this selection.
1141
SL Dir Int Tx0
Provides integer data for Direct Transmit word 0, if the data type for word 0 indicated in
Par 1140 [Tx Dir Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1142
SL Dir Real Tx0
Provides floating point (real) data for Direct Transmit word 0, if the data type for word 0
indicated in Par 1140 [Tx Dir Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1143
SL Dir Int Tx1
Provides integer data for Direct Transmit word 1, if the data type for word 1 indicated in
Par 1140 [Tx Dir Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1144
SL Dir Real Tx1
Provides floating point (real) data for Direct Transmit word 1, if the data type for word 1
indicated in Par 1140 [Tx Dir Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1145
SL Dir Int Tx2
Provides integer data for Direct Transmit word 2, if the data type for word 2 indicated in
Par 1140 [Tx Dir Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1146
SL Dir Real Tx2
Provides floating point (real) data for Direct Transmit word 2, if the data type for word 2
indicated in Par 1140 [Tx Dir Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1147
SL Dir Int Tx3
Provides integer data for Direct Transmit word 3, if the data type for word 3 indicated in
Par 1140 [Tx Dir Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1148
SL Dir Real Tx3
Provides floating point (real) data for Direct Transmit word 3, if the data type for word 3
(indicated in Par 1140 [Tx Dir Data Type]) is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1160
Tx Buf Data Type
Indicates the data type of each Buffered Transmit word. If the word's bit is set the data type is floating point (real). If the word’s bit is not set the data type is integer.
Use the Peer Communication window to configure this selection.
1161
SL Buf Int Tx00
Provides integer data for Direct Transmit word 0, if the data type for word 0 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1162
SL Buf Real Tx00
Provides floating point (real) data for Direct Transmit word 0, if the data type for word 0
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1163
SL Buf Int Tx01
Provides integer data for Direct Transmit word 1, if the data type for word 1 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1164
SL Buf Real Tx01
Provides floating point (real) data for Direct Transmit word 1, if the data type for word 1
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
1165
SL Buf Int Tx02
Provides integer data for Direct Transmit word 2, if the data type for word 2 indicated in
Par 1160 [Tx Buf Data Type] is integer.
Default:
Min/Max:
0
-/+2147483648
✓ ✓ 32-bit
Integer
1166
SL Buf Real Tx02
Provides floating point (real) data for Direct Transmit word 2, if the data type for word 2
indicated in Par 1160 [Tx Buf Data Type] is real.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓ ✓ Real
No.
Name
Description
Values
Li
nkab
le
Read
-Wr
it
e
Da
ta
T
ype
Options
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Real Tx3
Real Tx2
Real Tx1
Real Tx0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Rese
rv
ed
Rese
rv
ed
Real Tx29
Real Tx28
Real Tx27
Real Tx26
Real Tx25
Real Tx24
Real Tx23
Real Tx22
Real Tx21
Real Tx20
Real Tx19
Real Tx18
Real Tx17
Real Tx16
Real Tx15
Real Tx14
Real Tx13
Real Tx12
Real Tx11
Real Tx10
Real Tx9
Real Tx8
Real Tx7
Real Tx6
Real Tx5
Real Tx4
Real Tx3
Real Tx2
Real Tx1
Real Tx0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True