Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 122

3-68
Programming and Parameters
704
Fault Clr Owner
Indicates which adapter is currently clearing a fault.
707
Data In A1 Int
Link A Word 1 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
708
Data In A1 Real
Link A Word 1 (Real or Floating Point) - Parameters that can only be changed while the
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
709
Data In A2 Int
Link A Word 2 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
710
Data In A2 Real
Link A Word 2 (Real or Floating Point) - Parameters that can only be changed while the
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
711
Data In B1 Int
Link B Word 1 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
712
Data In B1 Real
Link B Word 1 (Real or Floating Point) - Parameters that can only be changed while the
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
713
Data In B2 Int
Link B Word 2 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
714
Data In B2 Real
Link B Word 2 (Real or Floating Point) - Parameters that can only be changed while the
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
715
Data In C1 Int
Link C Word 1 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
716
Data In C1 Real
Link C Word 1 (Real or Floating Point) - Parameters that can only be changed while the
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Min/ Max:
0.0000
-/+2200000000.0000
Real
No.
Name
Description
Values
Li
nkab
le
Read
-Wr
it
e
Da
ta
T
ype
Options
Unde
fined
Unde
fined
Unde
fined
Unde
fined
Unde
fined
Unde
fined
Unde
fined
Unde
fined
Dr
iv
eLog
ix
Res
er
ved
In
t DPI
Co
nn
Res
er
ved
A
ux
DP
I Conn
Ext DPI Con
n
Loc
al HI
M
Te
rm
inal Blk
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True