Configuring port parameters – Allied Telesis AT-S63 User Manual
Page 106
Chapter 6: Port Parameters
106
Section I: Basic Features
Configuring Port Parameters
To configure the most basic parameter settings for a port, perform the
following procedure:
1. From the Main Menu, type 1 to select Port Configuration.
The Port Configuration menu is shown in Figure 26.
Figure 26. Port Configuration Menu
2. From the Port Configuration menu, type 1 to select Port
Configuration.
The following prompt is displayed:
Enter port-list ->
3. Enter the number of the port you want to configure. You can specify
more than one port at a time. You can specify ports individually (for
example, 5,7,22), as a range (for example, 18-23), or both (for example
1,5,14-22). You cannot specify nonconsecutive ports (for example,
5,7,9).
Note
To configure SFP or GBIC port 23 or 24, the port must have a valid
link to an end node. If no SFP or GBIC is installed or if it does not have
a valid link, your configuration changes affect the corresponding
twisted pair port, 23R or 24R. You cannot configure twisted pair port
23R or 24R if its corresponding SFP or GBIC port has a valid link to an
end node.
Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63
Marketing
User: Manager
11:20:02 02-Oct-2004
Port Configuration
1 - Port Configuration
2 - Port Status
3 - Port Statistics
4 - Port Trunking
5 - Port Security
6 - Port Mirroring
R - Return to Previous Menu
Enter your selection?