Brocade FastIron Ethernet Switch Administration Guide User Manual
Page 79
Port8/5 is configured for link-error-disable
threshold:4, sampling_period:10, waiting_period:2
Port8/9 is configured for link-error-disable
threshold:2, sampling_period:20, waiting_period:0
For FastIron X Series devices, the output of the command shows the following.
device# show link-error-disable all
Port -----------------Config--------------- ------Oper----
# Threshold Sampling-Time Shutoff-Time State Counter
----- --------- ------------- ------------ ----- -------
11 3 120 600 Idle N/A
12 3 120 500 Down 424
Displaying ports configured with port flap dampening
defines the port flap dampening statistics
displayed by the show link-error-disable all command.
Output of show link-error-disable
TABLE 9
Column
Description
Port #
The port number.
Threshold
The number of times the port link state will go from up to down and down to up before the wait
period is activated.
Sampling-Time The number of seconds during which the specified toggle threshold can occur before the wait
period is activated.
Shutoff-Time
The number of seconds the port will remain disabled (down) before it becomes enabled. A zero (0)
indicates that the port will stay down until an administrative override occurs.
State
The port state can be one of the following:
• Idle - The link is normal and no link state toggles have been detected or sampled.
• Down - The port is disabled because the number of sampled errors exceeded the configured
threshold.
• Err - The port sampled one or more errors.
Counter
• If the port state isIdle , this field displays N/A .
• If the port state is Down , this field shows the remaining value of the shutoff timer.
• If the port state is Err , this field shows the number of errors sampled.
Syntax: show link-error-disable [ all ]
Also, in FastIron X Series devices, the show interface command indicates if the port flap dampening
feature is enabled on the port.
device# show interface ethernet 15
GigabitEthernet15 is up, line protocol is up
Link Error Dampening is Enabled
Port up for 6 seconds
Hardware is GigabitEthernet, address is 0000.0000.010e (bia 0000.0000.010e)
Configured speed auto, actual 1Gbit, configured duplex fdx, actual fdx
Configured mdi mode AUTO, actual MDIX
device# show interface ethernet 17
GigabitEthernet17 is ERR-DISABLED, line protocol is down
Link Error Dampening is Enabled
Port down for 40 seconds
Hardware is GigabitEthernet, address is 0000.0000.010e (bia 0000.0000.010e)
Configured speed auto, actual unknown, configured duplex fdx, actual unknown
Basic Software Features
FastIron Ethernet Switch Administration Guide
79
53-1003075-02