Digital optical monitoring – Brocade FastIron Ethernet Switch Administration Guide User Manual
Page 211
Supported fiber optic transceivers (Continued)
TABLE 28
Label
Type
Brocade part number
Supports Digital
Optical Monitoring?
10G-XFP-ZR
10GBase-ZR XFP, 80 km
33014-000
Yes
10G-XFP-ZRD
10GBase-ZRD XFP, 80 km
33063-000 to 33107-000 Yes
10G-SFPP-SR
10GE SR SFP+
57-0000075-01
Yes
10G-SFPP-LR
10GE LR SFP+
57-0000076-01
Yes
10G-SFPP-TWX-0101 FCoE 1M Active Cable
58-1000026-01
No
10G-SFPP-TWX-0301 FCoE 3M Active Cable
58-1000027-01
No
10G-SFPP-TWX-0501 FCoE 5M Active Cable
58-1000023-01
No
10G-SFPP-ER
10GBase-ER SFP+, 40 km
57-0000085-01
Yes
10G-SFPP-LRM
10GBase-LRM SFP+
57-0000084-01
Yes
E1MG-LHB
1000Base-LHB
33004-000
No
10G-SFPP-USR
10GE Ultra Short Reach (USR) SFP
+ 100m on OM3 MMF
57-1000130-01
Yes
40G-QSFP-C-0101
40GE QSFP Direct Attached Copper
Cable, 1m (stacking)
Used for stacking only.
58-0000033-01
No
40G-QSFP-C-0501
40GE QSFP Direct Attached Copper
Cable, 5m (stacking)
Used for stacking only.
58-0000035-01
No
Digital optical monitoring
You can configure your Brocade device to monitor optical transceivers in the system, either globally or
by specified ports. When this feature is enabled, the system will monitor the temperature and signal
power levels for the optical transceivers in the specified ports. Console messages and Syslog
messages are sent when optical operating conditions fall below or rise above the XFP, SFP, and SFP+
manufacturer recommended thresholds.
Digital optical monitoring configuration limitations
A Brocade chassis device can monitor a maximum of 24 SFPs and 12 XFPs.
Digital optical monitoring
FastIron Ethernet Switch Administration Guide
211
53-1003075-02