Field definitions for the show inline power detail command (Continued)

TABLE 42

Column

Definition

#Ports Off-Denied

The number of ports on the Interface module that were denied power because of
insufficient power.

#Ports Off-No-PD

The number of ports on the Interface module to which no PDs are connected.

#Ports Off-Fault

The number of ports on the Interface module that are not receiving power because
of a subscription overload.

Total

The totals for all of the fields in the Cumulative Port State Data report.

Cumulative port power data

Slot

The Interface module / slot number.

#Ports Pri: 1

The number of PoE ports on the Interface module that have a PoE port priority of
1.

#Ports Pri: 2

The number of PoE ports on the Interface module that have a PoE port priority of
2.

#Ports Pri: 3

The number of PoE ports on the Interface module that have a PoE port priority of
3.

Power Consumption

The total number of watts consumed by PoE power consuming devices, plus any
cable loss.

Power Allocation

The number of watts allocated to the Interface module PoE ports. This value is the
sum of the ports’ default or configured maximum power levels, or power classes
automatically detected by the FastIron PoE device.

Power Budget

The power budget allocated to the slot. The default value is 65535 watts. Any
other value indicates that the power budget was configured using the CLI
command inline power budget .

Total

The totals for all of the fields in the Cumulative Port Power Data report.

Inline power on PoE LAG ports

Allows for inline power to be enabled on PoE LAG ports.

The inline power on Power over Ethernet (PoE) LAG ports feature allows you to enable inline power
on PoE LAG ports with the introduction of a new command inline power ethernet that is available in
global configuration mode. Without this command, you cannot enable inline power on any secondary
LAG ports because the interface configuration mode is not available for LAG secondary ports to run
theinline power command.

Inline power on PoE LAG ports

288

FastIron Ethernet Switch Administration Guide