Field definitions for the show inline power detail command (Continued)

TABLE 42

Column

Definition

H/W Status

The PoE power supply hardware status code. This field is used by Brocade
Technical Support for troubleshooting.

Max Curr

The PoE power supply maximum current capacity.

Voltage

The PoE power supply current input voltage.

Capacity

The PoE power supply total power capacity (in watts).

PoE Capacity

The PoE power supply PoE power capacity (in watts).

Consumption

The total number of watts consumed by PoE power consuming devices and PoE
modules in the system, plus any internal or cable power loss.

NOTE
Under thelower total inline power consumption level by Powered Devices (PDs) on
FastIron SX devices, the power consumption displayed by the power supply units
(PSUs) is inaccurately displayed as lower than the actual power consumption of
the PSUs due to the sensitivity limitations of power supply measurements.

General PoE data

Slot

The Interface module / slot number.

Firmware Version

The Interface module / slot number firmware version.

Cumulative port state data

NOTE
When you enable a port using the CLI, it may take 12 or more seconds before the operational state of that port is
displayed correctly in the show inline power output.

Slot

The Interface module / slot number.

#Ports Admin-On

The number of ports on the Interface module on which the inline power command
was issued.

#Ports Admin-Off

The number of ports on the Interface module on which the inline power command
was not issued.

#Ports Oper-On

The number of ports on the Interface module that are receiving inline power from
the PoE power supply.

#Ports Oper-Off

The number of ports on the Interface module that are not receiving inline power
from the PoE power supply.