sysmon xbar link
Configures the sysmon parameters for the crossbar link. The no form of this command resets the
parameters to default values.
Syntax
sysmon xbar link { threshold events polling-interval | log-backoff value | action { none | syslog } }
no sysmon xbar link
Parameters
threshold
Defines the failure threshold for the fabric adapter error-count event. The threshold is
defined as N/W, where N is the number of events, and W is the number of consecutive
polling periods. When the threshold is reached, actions configured for this event type will
take place. Note that a threshold of 1/W implies that there is no threshold, and no event will
be triggered.
events
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
polling-interval
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
log-backoff
If an error condition persists, it will be continuously logged (internally and/or externally). The
log back-off count skips configured number of logs before logging again. This avoids
overflow of the internal log or of the syslog.
action
Specifies the action to take when the error count exceeds the specified threshold and log
back-off values.
none
No action is taken.
syslog
The error is logged to syslog.
Modes
Global configuration mode.
Usage Guidelines
This command is supported only on FSX devices.
Examples
The following example configures system monitoring for cross bar link errors:
Brocade(config)# sysmon xbar link threshold 3 7
Brocade(config)# sysmon xbar link action syslog