Viewing optical transceiver thresholds
The thresholds that determine the alarm status values for an optical transceiver are set by the
manufacturer of the XFP, SFP, or SFP+. To view the thresholds for a qualified optical transceiver in a
particular port, use the show optic threshold command as shown below.
device>show optic threshold 2/2
Port 2/2 sfp monitor thresholds:
Temperature High alarm 5a00 90.0000 C
Temperature Low alarm d300 -45.0000 C
Temperature High warning 5500 85.0000 C
Temperature Low warning d800 -40.0000 C
Supply Voltage High alarm 9088
Supply Voltage Low alarm 7148
Supply Voltage High warning 8ca0
Supply Voltage Low warning 7530
TX Bias High alarm 7530 60.000 mA
TX Bias Low alarm 01f4 1.000 mA
TX Bias High warning 61a8 50.000 mA
TX Bias Low warning 05dc 3.000 mA
TX Power High alarm 1f07 -001.0001 dBm
TX Power Low alarm 02c4 -011.4996 dBm
TX Power High warning 18a6 -001.9997 dBm
TX Power Low warning 037b -010.5012 dBm
RX Power High alarm 2710 000.0000 dBm
RX Power Low alarm 0028 -023.9794 dBm
RX Power High warning 1f07 -001.0001 dBm
RX Power Low warning 0032 -023.0102 dBm
Syntax:show optic threshold port
For Temperature, Supply Voltage, TX Bias, TX Power, and RX Power, values are displayed for each
of the following four alarm and warning settings: High alarm, Low alarm, High warning, and Low
warning. The hexadecimal values are the manufacturer internal calibrations, as defined in the
SFF-8472 standard. The other values indicate at what level (above the high setting or below the low
setting) the system should send a warning message or an alarm. Note that these values are set by the
manufacturer of the optical transceiver, and cannot be configured.
Syslog messages for optical transceivers
The system generates Syslog messages for optical transceivers in the following circumstances:
• The temperature, supply voltage, TX Bias, TX power, or TX power value goes above or below the
high or low warning or alarm threshold set by the manufacturer.
• The optical transceiver does not support digital optical monitoring.
• The optical transceiver is not qualified, and therefore not supported by Brocade.
For details about the above Syslog messages, refer to
Syslog messages for optical transceivers
Viewing optical transceiver thresholds