Viewing optical transceiver thresholds

The thresholds that determine the alarm status values for an optical transceiver are set by the
manufacturer of the XFP, SFP, or SFP+. To view the thresholds for a qualified optical transceiver in a
particular port, use the show optic threshold command as shown below.

device>show optic threshold 2/2

Port 2/2 sfp monitor thresholds:

Temperature High alarm 5a00 90.0000 C

Temperature Low alarm d300 -45.0000 C

Temperature High warning 5500 85.0000 C

Temperature Low warning d800 -40.0000 C

Supply Voltage High alarm 9088

Supply Voltage Low alarm 7148

Supply Voltage High warning 8ca0

Supply Voltage Low warning 7530

TX Bias High alarm 7530 60.000 mA

TX Bias Low alarm 01f4 1.000 mA

TX Bias High warning 61a8 50.000 mA

TX Bias Low warning 05dc 3.000 mA

TX Power High alarm 1f07 -001.0001 dBm

TX Power Low alarm 02c4 -011.4996 dBm

TX Power High warning 18a6 -001.9997 dBm

TX Power Low warning 037b -010.5012 dBm

RX Power High alarm 2710 000.0000 dBm

RX Power Low alarm 0028 -023.9794 dBm

RX Power High warning 1f07 -001.0001 dBm

RX Power Low warning 0032 -023.0102 dBm

Syntax:show optic threshold port

For Temperature, Supply Voltage, TX Bias, TX Power, and RX Power, values are displayed for each
of the following four alarm and warning settings: High alarm, Low alarm, High warning, and Low
warning. The hexadecimal values are the manufacturer internal calibrations, as defined in the
SFF-8472 standard. The other values indicate at what level (above the high setting or below the low
setting) the system should send a warning message or an alarm. Note that these values are set by the
manufacturer of the optical transceiver, and cannot be configured.

Syslog messages for optical transceivers

The system generates Syslog messages for optical transceivers in the following circumstances:

• The temperature, supply voltage, TX Bias, TX power, or TX power value goes above or below the

high or low warning or alarm threshold set by the manufacturer.

• The optical transceiver does not support digital optical monitoring.
• The optical transceiver is not qualified, and therefore not supported by Brocade.

For details about the above Syslog messages, refer to

Syslog messages for optical transceivers

.

Viewing optical transceiver thresholds

216