Relay Agent Information option: Disabled

Egress queues:

Queue counters Queued packets Dropped Packets

0 0 0

1 0 0

2 1 0

3 0 0

4 0 0

5 0 0

6 0 0

7 215703 0

Syntax: show interface [ ethernet port]

Specify the port variable in the format stack-unit/slotnum/portnum.

Egress queue statistics

TABLE 34

Parameter

Description

Queue counters

The QoS traffic class.

Queued packets

The number of packets queued on the port for the given traffic class.

Dropped packets The number of packets for the given traffic class that were dropped because of congestion.

Viewing egress queue counters on ICX 7750 devices

Viewing egress queue counters on ICX 7750 devices.

For a port, the show interface command displays the number of packets that were queued for each
QoS priority (traffic class) and dropped because of congestion. The egress queue counters are
displayed at the end of the show interface command output as shown in the following example.

NOTE
This command output displays the total of unicast and multicast counters for any particular QOS
priority.

Brocade# show interface ethernet 1/1/1

10GigabitEthernet 1/1/1 is down, line protocol is down

Port down for 16 hours 16 minutes 48 seconds

Hardware is 10GigabitEthernet , address is 748e.f8f9.6280 (bia 748e.f8f9.6280)

Interface type is 40Gig Fiber

Configured speed 40Gbit, actual unknown, configured duplex fdx, actual unknown

Configured mdi mode AUTO, actual unknown

Member of L2 VLAN ID 1, port is untagged, port state is BLOCKING

BPDU guard is Disabled, ROOT protect is Disabled, Designated protect is Disabled

Link Error Dampening is Disabled

STP configured to ON, priority is level0, mac-learning is enabled

Flow Control is enabled

Mirror disabled, Monitor disabled

Mac-notification is disabled

Not member of any active trunks

Not member of any configured trunks

No port name

IPG MII 96 bits-time, IPG GMII 96 bits-time

MTU 1500 bytes

300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization

300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization

0 packets input, 0 bytes, 0 no buffer

Received 0 broadcasts, 0 multicasts, 0 unicasts

0 input errors, 0 CRC, 0 frame, 0 ignored

0 runts, 0 giants

0 packets output, 0 bytes, 0 underruns

Transmitted 0 broadcasts, 0 multicasts, 0 unicasts