Poe and cpu utilization, Enabling and disabling power over ethernet – Brocade FastIron Ethernet Switch Administration Guide User Manual
Page 272
PoE Info: FW Download on slot 1...erase command...accepted.
PoE Info: FW Download on slot 1...erasing firmware memory...
PoE Info: FW Download on slot 1...erasing firmware memory...completed
PoE Info: FW Download on slot 1...sending program command...
PoE Info: FW Download on slot 1...sending program command...accepted.
PoE Info: FW Download on slot 1...programming firmware...takes around 6
minutes....
Brocade(config)#U1-MSG: PoE Info: Firmware Download on slot 1.....10 percent
completed.
!!! Temperature is over warning level on stack unit 1 !!!
U1-MSG: PoE Info: Firmware Download on slot 1.....20 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....30 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....40 percent completed.
!!! Temperature is over warning level on stack unit 1 !!!
U1-MSG: PoE Info: Firmware Download on slot 1.....50 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....60 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....70 percent completed.
!!! Temperature is over warning level on stack unit 1 !!!
U1-MSG: PoE Info: Firmware Download on slot 1.....80 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....90 percent completed.
U1-MSG: PoE Info: Firmware Download on slot 1.....100 percent completed.
PoE Info: FW Download on slot 1...programming firmware...completed.
PoE Info: FW Download on slot 1...upgrading firmware...completed. Module will
be reset.
3. After downloading the firmware file into the device, the device resets and reboots with the new PoE
firmware. You should see output similar to the following:
PoE Info: Resetting in slot 1....
!!! Temperature is over warning level on stack unit 1 !!!
PoE Info: Resetting module in slot 1....completed.
PoE Info: Programming Brocade defaults.....
PoE Info: Programming Brocade defaults. Step 1: Writing port defaults on
module in slot 1....
PoE Info: Programming Brocade Defaults: Step 2: Writing PM defaults on module
in slot 1.
PoE Info: Programming Brocade defaults. Step 3: Writing user byte 0xf0 on
module in slot 1.
PoE Info: Programming Brocade defaults. Step 4: Saving settings on module in
slot 1.
PoE Info: Programming Brocade defaults....completed
PoE and CPU utilization
Depending on the number of PoE-configured ports that have powered power devices, there may be a
slight and noticeable increase of up to 15 percent in CPU utilization. In typical scenarios, this is normal
behavior for PoE and does not affect the functionality of other features on the switch.
Enabling and disabling Power over Ethernet
To enable a port to receive inline power for power consuming devices, enter commands such as the
following.
device#configure terminal
device(config)# interface ethernet 1/1
device(config-if-e1000-1/1)# inline power
After entering the above commands, the console displays the following message.
device(config-if-e1000-1/1)#PoE Info: Power enabled on port 1/1.
Syntax: [no] inline power
Use the no form of the command to disable the port from receiving inline power.
PoE and CPU utilization
272
FastIron Ethernet Switch Administration Guide