Brocade FastIron Ethernet Switch Administration Guide User Manual

Page 257

background image

Port 5/19, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/18, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/17, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 5/16, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 5/15, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 5/14, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 5/13, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/12, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/11, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/10, configured rate=512, actual rate=512, Subsampling factor=1

Port 4/1, configured rate=10000, actual rate=32768, Subsampling factor=1

Port 1/26, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/25, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/15, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/12, configured rate=512, actual rate=512, Subsampling factor=1

...continued on next page...

...continued from previous page...

Port 1/11, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/10, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/9, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/8, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/7, configured rate=1000, actual rate=2048, Subsampling factor=4

Port 1/6, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/5, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/4, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/3, configured rate=512, actual rate=512, Subsampling factor=1

Port 1/2, configured rate=1000, actual rate=2048, Subsampling factor=4

Syntax: show sflow

The show sflow command displays the following information.

sFlow information

TABLE 36

Parameter

Definition

sFlow version

The version of sFlow enabled on the device, which can be one of the following:

• 2
• 5

sFlow services

The feature state, which can be one of the following:

• disabled
• enabled

sFlow agent IP address

The IP address that sFlow is using in the agent_address field of packets sent to the
collectors. Refer to

sFlow and source address

on page 246.

Collector

The collector information. The following information is displayed for each collector:

• IP address
• UDP port

If more than one collector is configured, the line above the collectors indicates how
many have been configured.

Configured UDP source
port

The UDP source port used to send data to the collector.

Polling interval

The port counter polling interval.

Network Monitoring

FastIron Ethernet Switch Administration Guide

257