beautypg.com

Table 3-3 log message flash levels -34 – SMC Networks SMC TigerStack III SMC6824MPE User Manual

Page 84

background image

C

ONFIGURING

THE

S

WITCH

3-34

The System Logs page allows you to configure and limit system messages
that are logged to flash or RAM memory. The default is for event levels 0
to 3 to be logged to flash and levels 0 to 7 to be logged to RAM.

Note: The level of messages logged to flash must be equal to or less than

the level of messages logged to RAM.

Command Attributes

System Log Status – Enables/disables the logging of debug or error
messages to the logging process.

Flash Level – Limits log messages saved to the switch’s permanent
flash memory for all levels up to the specified level. For example, if
level 3 is specified, all messages from level 0 to level 3 will be logged to
flash. (Range: 0-7, Default: 3).

* There are only Level 2, 5 and 6 error messages for the current firmware release.

RAM Level – Limits log messages saved to the switch’s temporary
RAM memory for all levels up to the specified level. For example, if
level 7 is specified, all messages from level 0 to level 7 will be logged to
RAM. (Default: 6)

Table 3-3 Log Message Flash Levels

Level

Severity Name

Description

7

Debug

Debugging messages

6

Informational

Informational messages only

5

Notice

Normal but significant condition, such as
cold start

4

Warning

Warning conditions (e.g., return false,
unexpected return)

3

Error

Error conditions (e.g., invalid input,
default used)

2

Critical

Critical conditions (e.g., memory
allocation, or free memory error - resource
exhausted)

1

Alert

Immediate action needed

0

Emergency

System unusable