Configuring Event Logging
The switch allows you to control the logging of error messages, including
the type of events that are recorded in switch memory, logging to a remote
System Log (syslog) server, and displays a list of recent event messages.
System Log Configuration
The system allows you to enable or disable event logging, and specify
which levels are logged to RAM or flash memory.
Severe error messages that are logged to flash memory are permanently
stored in the switch to assist in troubleshooting network problems. Up to
4096 log entries can be stored in the flash memory, with the oldest entries
being overwritten first when the available log memory (256 kilobytes) has
been exceeded.
Console(config)#line vty
Console(config-line)#login local
Console(config-line)#password 0 secret
Console(config-line)#timeout login response 300
Console(config-line)#exec-timeout 0
Console(config-line)#password-thresh 3
Console(config-line)#end
Console#show line
Console configuration:
Password threshold: 5 times
Interactive timeout: Disabled
Login timeout: Disabled
Silent time: 60
Baudrate: auto
Databits: 8
Parity: none
Stopbits: 1
VTY configuration:
Password threshold: 3 times
Interactive timeout: 600 sec
Login timeout: 300 sec
Console#