C
OMMAND
L
INE
I
NTERFACE
4-180
• When using the negotiation command to enable auto-negotiation, the
optimal settings will be determined by the capabilities command. To
enable flow control under auto-negotiation, “flowcontrol” must be
included in the capabilities list for any port
• Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals
may degrade overall performance for the segment attached to the hub.
Example
The following example enables flow control on port 5.
Related Commands
negotiation (4-177)
capabilities (flowcontrol, symmetric) (4-178)
shutdown
Use this command to disable an interface. To restart a disabled interface, use
the no form.
Syntax
[no] shutdown
Default Setting
All interfaces are enabled.
Command Mode
Interface Configuration (Ethernet, Port Channel)
Console(config)#interface ethernet 1/5
Console(config-if)#flowcontrol
Console(config-if)#no negotiation
Console(config-if)#