Samsung S3C2440A User Manual
Page 421
![background image](/manuals/143554/421/background.png)
S3C2440A RISC MICROPROCESSOR
ADC AND TOUCH SCREEN INTERFACE
16-9
ADC CONVERSION DATA REGISTER (ADCDAT1)
Register Address
R/W Description
Reset
Value
ADCDAT1
0x5800010
R
ADC Conversion Data Register
-
ADCDAT1 Bit
Description
Initial
State
UPDOWN
[15]
Up or Down state of Stylus at Waiting for Interrupt Mode.
0 = Stylus down state.
1 = Stylus up state.
-
AUTO_PST
[14]
Automatically sequencing conversion of X-Position and
Y-Position
0 = Normal ADC conversion.
1 = Sequencing measurement of X-position, Y-position.
-
XY_PST
[13:12]
Manually measurement of X-Position or Y-Position.
00 = No operation mode
01 = X-position measurement
10 = Y-position measurement
11 = Waiting for Interrupt Mode
-
Reserved [11:10]
Reserved
YPDATA
[9:0]
Y-Position Conversion data value
Data value : 0 ~ 3FF
-
ADC TOUCH SCREEN UP-DOWN INT CHECK REGISTER (ADCUPDN)
Register Address
R/W Description
Reset
Value
ADCUPDN
0x5800014
R/W
Stylus Up or Down Interrpt status
register
0x0
ADCUPDN Bit
Description
Initial
State
TSC_UP
[1]
Stylus Up Interrupt.
0 = No stylus up status.
1 = Stylus up interrupt occurred.
0
TSC_DN
[0]
Stylus Down Interrupt.
0 = No stylus down status.
1 = Stylus down interrupt occurred.
0