Coupling:phase:deviation – RIGOL DG1000Z Series User Manual
Page 30

RIGOL
2-18
DG1000Z Programming Guide
:COUPling:PHASe:DEViation
Syntax
:COUPling:PHASe:DEViation
:COUPling:PHASe:DEViation?
Description
Set the phase deviation in the phase coupling.
Query the phase deviation in the phase coupling.
Parameter
Name
Type
Range
Default
Real
-360° to 360°
0
Explanation
Select the desired phase coupling mode (
) and set the
corresponding phase deviation or phase ratio (
) before
enabling the phase coupling function (
). You cannot
set the phase coupling mode and phase deviation/ratio after the phase coupling
function is enabled.
When the phase coupling function is disabled, if the current phase coupling mode
is phase deviation, send this command can set the phase deviation; if the current
phase coupling mode is phase ratio, send this command can set the phase
coupling mode to phase deviation and set the phase deviation.
Return Format
The query returns the phase deviation in scientific notation. The return value contains
7 effective digits, for example, 9.000000E+01 (the phase deviation is 90°).
Example
:COUP:PHAS:DEV 90 /*Set the phase deviation in the phase coupling to 90°*/
:COUP:PHAS:DEV? /*Query the phase deviation in the phase coupling and the
query returns 9.000000E+01*/
Related
Commands
:COUPling:PHASe:MODE