Source:voltage comamnds, Source[]]:voltage:couple[:state, Source:voltage comamnds -180 – RIGOL DG1000Z Series User Manual
Page 192

RIGOL
2-180
DG1000Z Programming Guide
:SOURce:VOLTage Comamnds
[:SOURce[
Syntax
[:SOURce[
[:SOURce[
Description
Turn on or off the amplitude coupling function.
Query the on/off status of the amplitude coupling function.
Parameter
Name
Type
Range
Default
[
Discrete
1|2
1
{ON|1|OFF|0}
Bool
ON|1|OFF|0
OFF
Explanation
When the amplitude coupling is enabled, CH1 and CH2 take each other as the
reference source. When the amplitude of one channel (the reference source) is
changed, the amplitude of the other channel will be changed automatically and
always keeps the specified amplitude deviation or ratio with that of the reference
channel.
Please select the desired amplitude coupling mode (
) and
set the corresponding amplitude deviation (
) or
amplitude ratio (
) before enabling the amplitude coupling
function. You cannot set the amplitude coupling mode and the amplitude
deviation/ratio after the amplitude coupling function is enabled.
on/off status of the amplitude coupling function.
Return Format
The query returns ON or OFF.
Example
:SOUR1:VOLT:COUP ON /*Turn on the amplitude coupling function*/
:SOUR1:VOLT:COUP? /*Query the on/off status of the amplitude coupling
function and the query returns ON*/
Related
Commands
:COUPling:AMPL:MODE
:COUPling:AMPL:RATio