Coupling:ampl[:state – RIGOL DG1000Z Series User Manual
Page 25

RIGOL
DG1000Z Programming Guide
2-13
:COUPling:AMPL[:STATe]
Syntax
:COUPling:AMPL[:STATe] {ON|1|OFF|0}
:COUPling:AMPL[:STATe]?
Description
Enable or disable the amplitude coupling function.
Query the on/off status of the amplitude coupling function.
Parameter
Name
Type
Range
Default
{ON|1|OFF|0}
Bool
ON|1|OFF|0
OFF
Explanation
After the amplitude coupling function is enabled, CH1 and CH2 take each other as
the reference source. When the amplitude of a channel (this channel is the
reference source) is changed, the amplitude of the other channel changes
accordingly automatically and always keeps the specified amplitude deviation or
ratio with that of the reference channel.
Select the desired amplitude coupling mode (
) and set the
corresponding amplitude deviation (
) or amplitude
ratio (
) before enabling the amplitude coupling function.
You cannot set the amplitude coupling mode and amplitude deviation/ratio after
the amplitude coupling function is enabled.
[:SOURce[
set or query the on/off status of the amplitude coupling function.
Return Format
The query returns ON or OFF.
Example
:COUP:AMPL ON /*Enable the amplitude coupling function*/
:COUP:AMPL? /*Query the on/off status of the amplitude coupling function and
the query returns ON*/
Related
Commands
:COUPling:AMPL:MODE
:COUPling:AMPL:RATio
[:SOURce[