Source[]]:pulse:width – RIGOL DG1000Z Series User Manual
Page 170

RIGOL
2-158
DG1000Z Programming Guide
[:SOURce[
Syntax
[:SOURce[
[:SOURce[
Description
Set the pulse width of the specified channel.
Query the pulse width of the specified channel.
Parameter
Name
Type
Range
Default
[
Discrete
1|2
1
Real
16ns to 999.999 982 118 590 6ks
500us
Explanation
The pulse width is defined as the time interval between 50% of the amplitude
of a pulse rising edge to 50% of the amplitude of the next pulse falling edge.
The range of the pulse width is limited by the “minimum pulse width” and
“pulse period (for the ranges of the “minimum pulse width” and “pulse period”,
please refer to the “Signal Characteristics” of the “Specifications” in
DG1000Z
User’s Guide
). The actual range of the pulse width is
min
min
2
w
pulse
width
w
P
P
P
P
×
−
<
≤
Wherein,
width
P
——
pulse width;
min
w
P
——minimum pulse width;
pulse
P
——
pulse period.
When [:SOURce[
parameters of CH1 by default.
Return Format
The query returns the pulse width in scientific notation with 7 effective digits, for
example, 1.000000E-02 (the pulse width is 10ms, namely 0.01s).
Example
:SOUR1:FUNC:PULS:WIDT 0.01 /*Set the pulse width of CH1 to 10ms (namely
0.01s)*/
:SOUR1:FUNC:PULS:WIDT? /*Query the pulse width of CH1 and the query
returns 1.000000E-02*/