Source[]]:function:pulse:transition:trailing – RIGOL DG1000Z Series User Manual
Page 117

RIGOL
DG1000Z Programming Guide
2-105
[:SOURce[
Syntax
[:SOURce[
{
[:SOURce[
Description
Set the pulse fall time of the specified channel.
Query the pulse fall time of the specified channel.
Parameter
Name
Type
Range
Default
[
Discrete
1|2
1
Real
10ns to 0.625×pulse width
20ns
Explanation
The fall time is defined as the time required for the pulse amplitude to fall from
90% to 10%.
When [:SOURce[
parameters of CH1 by default.
The range of the fall time is limited by the current waveform frequency and pulse
width. When the specified value exceeds the limits, DG1000Z will adjust the edge
time automatically to make it match the specified pulse width.
Return Format
The query returns the pulse fall time in scientific notation with 7 effective digits, for
example, 3.500000E-08 (the pulse fall time is 35ns).
Example
:SOUR1:FUNC:PULS:TRAN:TRA 0.000000035 /*Set the pulse fall time of CH1 to
35ns*/
:SOUR1:FUNC:PULS:TRAN:TRA? /*Query the pulse fall time of CH1
and the query returns
3.500000E-08*/