4.1.10 EDIT KEYS
These keys are for editing a stored part program.
ERASE key:
Used for erasure of data in storage.
INSRT key:
Used for insertion of data in memory
A L T E R k e y :
Used for alteration of data in
memory.
Fig. 4.9
4.1.11 MEM DATA (MEMORY DATA) KEYS
TAPE KEYs
are to start the tape operation except
in the automatic operation mode.
They are effec-
tive only in the EDT mode.
. OUT key
This key is to
outputting various data in
memory through data I /0
interface.
IN key
This key is to start storing various data into
memory through tape reader or data I /0 inter-
face.
. VER key
This key is to start verifying between memory
data and punched tape data.
4.1.12 RESET KEY
This key resets the control.
LTER
F i g .
4.10
Auxiliary function cancel
Label skip function ON
pointer rewind
Sequence number reset
RST signal transmission
G code
Refer to 2.9.1, “ LIST OF G CODES AND GROUPS .“
The following will not be affected by operating the
RESET key.
Current position values of each axis.
. F commands
. S, T and B commands
Tool offset values, setting data, parameter data
Note :
Depressing the RESET key or the re-
mote reset pushbutton is defined as “Reset
in this manual.
4.2
POWER ON/OFF OPERATION
4.2.1 TURNING ON POWER
Check the machine before turning on power,
ferrin g to the machine tool b
manual for
details.
Operations after completion of
-
tions are as follows.
Depress the POWER ON pushbutton to turn on
the control power.
The internal timer will be
read in about two seconds.
Then the servo
power is ready for turning on, which is shown
by alarm code “ 310. “
Depress the POWER ON pushbutton again to
turn on the servo power. The NRD (NC READ-
Y) signal is sent out when the NC power is
normally supplied.
When the NRD signal turns on the machine
power, and the MRD (MACHINE READY) sig-
nal returns back to the control, the READY
lamp will be lit.
Operations to be executed by this RESET key are:
. Move command cancel
. Buffer register clear
. Alarm code release if the cause is eliminated
. Tool offset cancel