K2 Storage System Instruction Manual

87

Configuring RAID

NOTE: Leave Full Bind selected. Do not uncheck it.

b. In the

LUN TYPE

drop down box, for select

RAID 3

.

c. In the Available Disks box, select five contiguous disks at the top of the list.

(TIP: Use ‘shift-click’ or ‘control-click’ to select disks.)

d. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive light to flash.

e. Click

OK

to close the Binding LUN dialog box and begin the binding process.

The Progress Report dialog box opens, showing the status of the binding
process.

f. Close the Progress Report and repeat these steps for other unbound disks. If

specified by your system design, you can bind some disks as Hot Spares, as
explained in

“Binding Hot Spare drives” on page 369

. When you are done, if

you did not bind any extra Hot Spares, you should have the following results:

For Level two storage you should have three RAID 3 LUNs of five disks each
on a RAID storage device. If you have the optional Expansion chassis, you
would have an additional three RAID 3 LUNs of five disks each.

NOTE: Controllers can take several hours to bind a LUN. Make sure you initiate
multiple simultaneous binding processes to reduce the overall time.

g. Upon 100% completion, click

Close

in Progress Report window.

NOTE: Do not proceed until all LUNs are finished binding.

3. Restart the K2 Media Server.

NOTE: Make sure start up processes on the K2 Media Server are complete before
proceeding. This could take ten minutes.

4. Continue with the next procedure

“Creating a new file system”

.

This manual is related to the following products: