Chapter 2 Installing the Level 1 Storage System

snmp-server host public 192.168.40.11

19.Enable Authentication traps by typing the following:

snmp-server enable traps authentication

This allows NetCentral to test the switch to verify that it can send its SNMP trap
messages to NetCentral.

20.Type menu to get to menu mode. When prompted, save the configuration.

21.If you need a trunk for ISLs to gang switches together, use the following steps.

These steps illustrate trunking the last two ports for the two 10 Gig ISLs, which is
the recommended configuration for ISLs on all multi-switch K2 Storage Systems.
Refer to

“Design considerations for Ethernet switches” on page 376

and consult

with your Grass Valley representative if your requirements deviate from the
recommended policy:

a. At the main menu, select

Switch Configuration

.

b. Choose selection 2,

Port/Trunk Settings

.

c. Press the right-arrow key to choose

Edit

, then press

Enter

.

d. Down arrow until at the bottom of the list of ports.

e. Right-arrow over to the Group column.

f. Use the Space bar and set the bottom port to

Trk1

. On a switch with the 10 Gig

ISLs, this would be an ISL (Port 26).

g. Set the next port up also to

Trk1

. On a switch with the 10 Gig ISLs, this would

be the other ISL (Port 25).

h. Press

Enter

, then right-arrow to

Save

. Press

Enter

again and revert to previous

menu.

22.Return to the main menu.

23.From the main menu, tab to

Command Line (CLI)

and press

Enter

. The command

prompt appears.

24.Type show flash to check the version of firmware currently installed on the

switch. Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash

Image Size(Bytes) Date Version

----- ---------- -------- -------

Primary Image : 3287779 03/15/05 M.08.66

Secondary Image : 3287779 03/15/05 M.08.66

Boot Rom Version: I.08.07

Current Boot : Primary

25.Check the Primary Image Version and refer to K2 Storage System Release Notes

for information about currently supported versions and upgrade requirements.
Then proceed as follows: