Chapter 2 Installing the Level 1 Storage System

On this page…

Do this…

File System Server
Configuration

This page checks on the
configuration of the L1
device in one of its main
roles as a file system server.
The L1 device also functions
as a file system client, which
is also checked from this
page.

Click

Check

. When the wizard reports that the configuration is correct,

click

Next

.

If you get a “The V: will not be available until this device is rebooted…”
message, you can safely continue with this procedure and follow the
instructions related to this message later in the procedure.

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
RAID storage. You
configure network settings
on the iSCSI adapter and the
page validates that the media
LUNs are visible as iSCSI
targets.

Select the iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and subnet mask
and click

Apply

.

To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed. Note: The numbering of iSCSI target drives
here does not match the numbering of LUNs in Storage Utility since
LUN 0 (the system drive) is not an iSCSI target.
Click

Next

.