Configuring Level 3 RAID chassis network and SNMP settings

• Gateway Address

• SNMP trap destinations

For the Level 3 RAID chassis, network and SNMP settings are set and stored on the
RAID controller. Therefore, if the RAID chassis has two controllers, each controller
must be configured separately, as in the following procedure.

1. In the K2 System Configuration application tree view, open the node for a K2

Media Server and select the

File System Server

node to open its property page. On

the property page click

Launch Storage Utility

. Storage Utility opens.You can now

configure the network settings on the controller connected to the selected K2
Media Server.

2. In the Storage Utility, right-click the icon for a RAID controller and select

Configuration | Network Properties

. The Network Settings dialog box opens.

3. Enter network settings.

4. For each SNMP manager to which you want to send SNMP trap messages, enter

the IP address of the PC hosting the manager. For monitoring with NetCentral,
enter the IP address of the NetCentral server PC.

5. Click

OK

to save settings and close.

6. If you are working on a Level 3 RAID chassis with two RAID controllers, repeat

this procedure except in the K2 System Configuration select the K2 Media Server
connected to the other RAID controller.

7. Restart the RAID chassis to put SNMP configuration changes into effect.