beautypg.com

Chapter 7 installing the nearline storage system – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 292

background image

292

K2 Storage System Instruction Manual

September 6, 2006

Chapter 7 Installing the Nearline Storage System

3. If you got a “The V: will not be available until this device is rebooted…” message

on the File System Server Configuration page, after the K2 Media Server restarts,
do the following:

a. In the K2 System Configuration application tree view, under the K2 Media

Server select the File System Server node.

The File System Server Configuration page appears.

b. Click

Check

and verify that the V: drive is shared. This is required for NAS

server functionality.

File System Server
Configuration

This page checks on the
configuration of the media
server in one of its main
roles as a file system server.
The media server also
functions as a file system
client, which is also checked
from this page.

It is not necessary to bind
LUNs or create a file system,
since those tasks were
completed when you
configured the first media
server. However, if the Level
3 RAID chassis has two
controllers, you must launch
Storage Utility from this
page when you are
configuring one of the media
servers connected to the
second controller. You do
this to configure controller
network settings and to
verify controller microcode.

If the RAID chassis has two controllers, when configuring a media
server connected to the second controller click

Launch Storage Utility

.

In the Storage Utility tree view, select the icon for the RAID controller
and check its microcode version, as explained in

“Verifying controller

microcode” on page 281

. Then right-click the controller and select

Configuration | Network Properties

. Enter network and SNMP settings,

then close dialog boxes and Storage Utility to return to this page. Refer
to

“Configuring RAID network and SNMP settings” on page 281

for

similar Storage Utility procedures.

Click

Check

. Confirm a “… default.cfg file copied…” message. When

the wizard reports that the configuration check is successful, click

Next

.

and

Yes

to confirm copying default.cfg to the server.

If you get a “The V: will not be available until this device is rebooted…”
message, you can safely continue with this procedure and follow the
instructions related to this message later in the procedure.

Completing the
Configuration Wizard

Click

Finish

. The wizard closes. The K2 Media Server restarts. Do not

proceed until restart processes are finished. If you are not sure if startup
is complete, wait 10 minutes.

On this page…

Do this…

This manual is related to the following products: