Setting up the Nearline GigE switches

NOTE: If the switch is used for the Nearline system only and there is no K2 media
(real-time iSCSI) traffic on the switch, there is no need for VLANs or dedicated
“media” ports.

If you have one switch for the Nearline system, connect as follows:

• Make two connections (control and FTP) from each media server, one

connection from each RAID controller, and one connection from the control
point PC.

If you have two switches for the Nearline system, connect as follows:

• To the ports on switch A, make a connection from RAID controller 0 and from

the control point PC. Also make two connections (control and FTP) from half of
the installed Nearline media servers.

• To the ports on switch B, make a connection from RAID controller 1, if it is

installed. Also make two connections (control and FTP) from the remaining
Nearline media servers.

Refer to

“Nearline system description” on page 256

for a diagram of the complete

system.

Refer to cabling procedures later in this chapter for the GigE connections at each of
the devices of the K2 Storage System.

Also refer to

“K2 Ethernet switch description” on page 299

and

“Design

considerations for Ethernet switches” on page 376

.

Configuring the GigE switch via serial connection

NOTE: Make sure you check the switch firmware and upgrade if necessary, as
instructed at the end of this procedure.

Use a direct console connection to the switch, start a console session, and access the
Switch Setup screen to set the IP address. The following procedure is for the HP
ProCurve switch, which is required for iSCSI traffic. If you are using a non-HP switch
for non-iSCSI traffic, accomplish the same tasks as appropriate. Consult the
documentation that came with the switch for more information.

1. Configure the PC terminal emulator on the control point PC or another PC as a

DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either one
to operate with these settings:

• Baud rate 115200

GigE Ports