Binding disk modules – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual
Page 127
September 6, 2006
K2 Storage System Instruction Manual
127
Configuring RAID
4. Enter the control network IP address and other network settings.
5. You want SNMP trap messages go to the NetCentral server PC, so for SNMP
Configuration enter the IP address of the NetCentral server PC. You can also enter
IP addresses for other SNMP managers to which you want to send SNMP trap
messages.
6. Click
OK
to save settings and close.
7. In Storage Utility click
View | Refresh
. Continue with the next procedure
“Binding
disk modules”
.
Binding disk modules
Use the following procedure to bind disk modules as required for the Level 2R storage
system.
NOTE: Binding destroys all user data on the disks.
1. In the Storage Utility main window, identify bound LUNs and unbound disks by
their placement in the hierarchy of the tree view. In the following illustration, disk
numbers are represented by “XX”. Refer to
“Identifying disks” on page 365
for an
explanation of how disks are actually numbered in Storage Utility.