Chapter 6 Installing the Level 3R Storage System

Configuring the redundant media server 2B

You must wait for server 2A to restart before continuing.

For Level 3 redundant, the last media server to configure is server 2B. It is the
redundant partner to server 2A.

1. In the K2 System Configuration application tree view, select the media server you

are configuring as server 2B.

2. Click the

Configure

button. The Configure K2 Server wizard opens. Follow the

on-screen text to configure the server for a Level 3R K2 Storage System, as
described in the following table. Some screens require no input from you, as they
are based on the configurations already completed on a previously configured

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
RAID storage. You
configure network settings
on the iSCSI adapter and the
page validates that the media
LUNs are visible as iSCSI
targets.

For Level 3 redundant, select

Primary

.

Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and subnet mask
and click

Apply

. Do the same for the other iSCSI adapter.

To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed.
Click

Next

.

Completing the
Configuration Wizard

Click

Finish

. The wizard closes. The K2 Media Server restarts. Do not

proceed until restart processes are finished. If you are not sure if startup
is complete, wait 10 minutes.