Power on the l3 raid chassis, Preparing k2 storage system clients – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual
Page 165

September 6, 2006
K2 Storage System Instruction Manual
165
Preparing K2 Storage System clients
Power on the L3 RAID chassis
Your preparations for L3 RAID storage are now complete.
Preparing K2 Storage System clients
Any devices that function as iSCSI clients to the K2 Storage System must be prepared
with the following requirements:
• One or more connections to the control network.
• A static IP address for the control network.
• If a Level 1, 2, or 3 (non-redundant) K2 Storage System, one connection to the
media (iSCSI) network.
• If a Level 2R, 3R or other redundant K2 Storage System, K2 Media Clients have
one connection to the A media (iSCSI) network and one connection to the B media
(iSCSI) network. Other iSCSI clients with just one media port connect to either the
A or the B network.
Additional steps that are required for Aurora Edits include the following:
POWER
SERVICE
K2
RAID STORAGE
!
Power Cords
(115V/230V)
Power-up Verification
DIR and SVP LEDs on the RAID controllers are blinking green
Disk Link LED is steady ON green.
FLT and BAT LEDs are OFF.
The front Power LED is ON, Service LED is OFF after about 5 minutes.
Refer to the L3 RAID Instruction Manual if there is a problem.
Power LED
Disk Link
LED
Disk Link
LED
Connect power cords, and turn on power as shown.
You must power-up any RAID Expansion chassis
prior to, or at the same time as the RAID Controller
chassis. Verify power-up as shown.
Service LED