beautypg.com

Chapter 6 installing the level 3r storage system – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 238

background image

238

K2 Storage System Instruction Manual

September 6, 2006

Chapter 6 Installing the Level 3R Storage System

File System Server
Configuration

This page checks on the
configuration of the media
server in one of its main
roles as a file system server.
The media server also
functions as a file system
client, which is also checked
from this page.

It is not necessary to bind
LUNs or create a file system,
since this task was
completed when you
configured the previous
media server. However, if
the Level 3R RAID chassis
has two controllers, you
must launch Storage Utility
from this page to configure
controller 1 network
settings.

If the RAID chassis has two controllers, click

Launch Storage Utility

.

In the Storage Utility tree view, right-click the icon for the RAID
controller, and select

Configuration | Network Properties

. Enter

network and SNMP settings, then close dialog boxes and Storage Utility
to return to this page. Refer to

“Configuring RAID network and SNMP

settings” on page 227

for similar Storage Utility procedures.

Click

Check

. Confirm a “… default.cfg file copied…” message. When

the wizard reports that the configuration check is successful, click

Next

.

and

Yes

to confirm copying default.cfg to the other server.

If you get a “The V: will not be available until this device is rebooted…”
message, you can safely continue with this procedure and follow the
instructions related to this message later in the procedure.

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
LUNs are visible as iSCSI
targets.

NOTE: The iSCSI
adapters on this
server must be on a
different subnet
than those on its
redundant server
partner.

For Level 3 redundant, select Backup.
Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and subnet mask
and click

Apply

. Do the same for the other iSCSI adapter.

To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed.
Click

Next

.

On this page…

Do this…

This manual is related to the following products: