Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual
Page 230

230
K2 Storage System Instruction Manual
September 6, 2006
Chapter 6 Installing the Level 3R Storage System
represented by the single “Controller” node)
The Bind LUN dialog box opens showing all unbound disks for the controller
listed in the Available Disk list.
NOTE: Leave Full Bind selected. Do not uncheck it.
b. In the
LUN TYPE
drop down box, select
RAID 5
. If specified by your system
design, RAID 6 is also supported. Refer to the Nearline chapter for more
information on RAID 6.
c. In the Available Disks box, select five contiguous disks at the top of the list.
(TIP: Use ‘shift-click’ or ‘control-click’ to select disks.).
d. Click the add (arrow) button to add disks to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click
Identify Disks.
This causes the disk drive light to flash.
e. Click
OK
to close the Binding LUN dialog box and begin the binding process.
The Progress Report dialog box opens, showing the status of the binding
process.