beautypg.com

Binding disk modules – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 180

background image

180

K2 Storage System Instruction Manual

September 6, 2006

Chapter 5 Installing the Level 3 Storage System

4. Enter the control network IP address and other network settings.

5. You want SNMP trap messages go to the NetCentral server PC, so for SNMP

Configuration enter the IP address of the NetCentral server PC. You can also enter
IP addresses for other SNMP managers to which you want to send SNMP trap
messages.

6. Click

OK

to save settings and close.

7. For a Level 3 RAID chassis with two controllers, you must also configure network

settings on the other controller. You can do this when you configure the K2 media
server connected to the other controller.

8. In Storage Utility click

View | Refresh

. Continue with the next procedure

“Binding

disk modules”

.

Binding disk modules

Use the following procedure to bind disk modules as required for the Level 3 storage
system.

NOTE: Binding destroys all user data on the disks.

1. In the Storage Utility main window, identify bound LUNs and unbound disks by

their placement in the hierarchy of the tree view. In the following illustration, disk
numbers are represented by “XX”. Refer to

“Identifying disks” on page 365

for an

explanation of how disks are actually numbered in Storage Utility.

This manual is related to the following products: